Sourcing metal door stops from China
Metal door stops from China carry 0% UK duty when classified as base-metal building-door fittings, with no trade remedy listed in the supplied record. Importers are responsible for the safety of consumer products. Confirm the mounting design and buffer retention before ordering. Cambridge China Bridge sources metal door stops.
Buying from China for a business? How our UK China sourcing agent service works · China sourcing agent for UK manufacturers and engineering firms

Duty and classification for metal door stops
Read from the UK Trade Tariff on 20 November 2026, heading 8302 covers base-metal mountings and fittings, including fittings for building doors. Fixed metal door stops are candidates for 8302 41 10 00. The table repeats this code for different mounting designs; these are product variants rather than separate tariff lines.
The supplied record shows 0% duty for goods from China under this code, with no anti-dumping or countervailing duty, suspension or attached import control. The luggage-handle suspension and supplementary-unit entry elsewhere in the heading concern different goods. Import VAT is separate from customs duty.
Send photographs, drawings, material details and the fixing method to your customs broker to confirm the commodity code. A loose weighted stop or a product mainly made of rubber needs its own classification assessment. For the wider door-stop comparison, see rubber door stops.
| Goods | Commodity code | Duty | Anti-dumping or countervailing duty on China |
|---|---|---|---|
| Floor-mounted metal door stops, subject to classification | 8302 41 10 00 | 0% | None |
Specify the mounting and contact point
Specify whether the stop mounts to the floor, wall, skirting or door. Give projection, base dimensions, fixing centres, screw details and door clearance. Position the buffer so it meets a suitable part of the door before the handle strikes the wall. Approve a fitted sample on the intended mounting surface.
Agree the metal grade, solid or hollow construction, finish, buffer material and method of retaining the buffer. Check whether replacement buffers are available. Importers are responsible for the safety of consumer products. Include sharp edges, detachable parts and foreseeable impacts in your product assessment.
Worked duty example
Illustrative example, not a quote: 2,000 floor-mounted metal door stops; illustrative order and values under 8302 41 10 00, invoiced at £7,000 free on board, with £600 of freight and insurance to the UK. The customs value is £7,600. Duty at 0% is £0. Import VAT at 20% is charged on the customs value plus duty, £7,600, so it is £1,520. With no duty, the only import tax is the VAT, which a VAT-registered importer can usually reclaim. The import duty and VAT guide explains each step.
Inspection checklist
Fit: compare projection, base dimensions and fixing centres with the approved drawing; fit samples using the supplied screws and plugs on the intended substrate.
Impact and retention: operate a representative door against the stop repeatedly; check for movement, bent stems, loose threaded joints and buffers that split or detach.
Material and finish: compare material records with the order; inspect for burrs, plating defects, corrosion and buffer marks on the intended door finish.
Packing and contents: check matching screws, plugs, cover plates and fitting instructions; separate metal surfaces to prevent scratches. Plan a shipment inspection.
Working out your own order? Send us the product on WhatsApp and we reply the same working day: WhatsApp us
What goes wrong
A stop can look correct yet project too little to protect the handle, meet a weak door panel or leave its fixings under excessive leverage. Thin bases can distort, threaded stems can loosen and poorly retained buffers can fall off. Compare production samples with the fitted reference sample.
Keep impact stops distinct from devices intended to hold doors open. England's fire-door guidance explains that a fire door which does not close fully will not adequately hold back fire and smoke. For fire-door applications, check the proposed stop position with the person responsible for the building's fire safety before ordering.
Cambridge China Bridge sources these products for UK businesses, checking the factory and the documents before shipment. See factory verification. For repeat volumes, see container programmes.
Frequently asked questions
What is the UK import duty on metal door stops from China?
The supplied record shows 0% under 8302 41 10 00 for base-metal building-door fittings, with no anti-dumping or countervailing duty listed. Confirm that this code fits the actual stop.
Which dimensions should I give the factory?
Show where the buffer should contact the door and identify the mounting surface.
How do I check that the rubber buffer stays attached?
Agree the retention design, then repeatedly operate a representative door against fitted samples. Check for splitting, rotation, loosening and detachment, and compare production samples with the approved sample.
Can a metal door stop be used beside a fire door?
Have the proposed position checked against the building's fire-safety arrangements. The stop should not prevent full closure; England's guidance explains that incomplete closure undermines fire and smoke protection.