Sourcing steel air receivers from China
Steel compressed-air receivers from China carry 2% UK duty across the selected lines, with no anti-dumping or countervailing duty recorded. Receivers requiring conformity marking need CE or UKCA marking and English instructions for the Great Britain market. Cambridge China Bridge sources steel compressed-air receivers.
Buying from China for a business? How our UK China sourcing agent service works · China sourcing agent for small orders and first imports

UK duty on steel compressed-air receivers
Read from the UK Trade Tariff on 1 October 2026, heading 7311 covers iron or steel containers for compressed or liquefied gas. Welded air receivers are divided by capacity; seamless designs have separate branches. All selected lines carry 2% duty for goods from China, with no recorded anti-dumping, countervailing or steel measure.
The snapshot lists a 0.00 % suspension restricted to empty portable medical oxygen cylinders fitted with a valve and pressure and flow regulator. Do not apply it to ordinary air receivers. It also attaches an import control of fluorinated greenhouse gases. The receiver-specific declaration requirement could not be confirmed: ask your customs broker to confirm the requirement for the actual contents and intended use before shipment.
Confirm the commodity code using construction, capacity, pressure and the complete goods description. The seamless rows are conditional candidates for matching designs, rather than alternatives for welded receivers. See the wider steel gas-cylinder guide for the rest of the heading.
| Goods | Commodity code | Duty | Anti-dumping or countervailing duty on China |
|---|---|---|---|
| Welded steel air receivers, capacity below 1 000 litres | 7311 00 91 00 | 2% | None |
| Welded steel air receivers, capacity 1 000 litres or more | 7311 00 99 00 | 2% | None |
| Other seamless steel air receivers, outside the refillable-cylinder description | 7311 00 30 85 | 2% | None |
| Other seamless air receivers, pressure 165 bar or more, capacity over 50 litres | 7311 00 19 85 | 2% | None |
Specify the receiver and its pressure-vessel category
Specify compressed-air service, steel grade, welded or seamless construction, working and test pressure, capacity, temperature range, wall thickness, orientation and support arrangement. Put inlet, outlet, drain, gauge and safety-valve connection sizes and threads on an approved drawing. Agree internal cleanliness, coating, inspection access and protection for ports during transport.
Ask the manufacturer to identify the applicable pressure-vessel rules and category for the exact design. Under the Simple Pressure Vessels (Safety) Regulations, Category A vessels must meet essential safety requirements before being placed on the market. For receivers requiring conformity marking, check CE or UKCA marking and English instructions. Request the declaration, design documents and test records covering the supplied model.
The Pressure Equipment (Safety) Regulations regulate design, manufacture and conformity assessment of pressure equipment above 0.5 bar. Ask the supplier to explain whether these rules or the simple pressure-vessel rules cover the receiver. Before qualifying pressure equipment is used, a written scheme of examination must be in place and an examination undertaken.
Worked duty example
Illustrative example, not a quote: Illustrative order of 50 welded steel compressed-air receivers under 7311 00 91 00, invoiced at £32,000 free on board, with £4,000 of freight and insurance to the UK. The customs value is £36,000. Duty at 2% is £720. Import VAT at 20% is charged on the customs value plus duty, £36,720, so it is £7,344. Import taxes total £8,064; a VAT-registered importer can usually reclaim the VAT, so the lasting cost is the £720 of duty. The import duty and VAT guide explains each step.
Inspection checklist
Identity and documents: match model, serial or batch identification, pressure and capacity on the receiver to the order, drawing and supplied documents. Check the applicable marking and English instructions.
Shell and supports: inspect weld appearance, dents, coating damage and corrosion. Compare accessible wall thickness, overall dimensions, feet and mounting holes with the approved specification.
Ports and fittings: gauge connection threads, check port positions and confirm that the drain is accessible in the installed orientation. Match supplied valves and gauges to the order.
Tests and cleanliness: review pressure-test records against the agreed procedure and receiver identity. Inspect accessible interiors for moisture, loose scale and debris, and check that ports are protected. Use the inspection guide to define the sampling brief.
Working out your own order? Send us the product on WhatsApp and we reply the same working day: WhatsApp us
What goes wrong
A receiver can match the advertised capacity but have unsuitable connection threads, inaccessible drainage or supports that do not fit the installation. Moisture trapped inside, damaged coating and debris in ports can also cause rejection. Resolve these points on the drawing and sample before production, then check the shipment against them.
A generic certificate may describe a different receiver model or pressure rating. Ask for documents that identify the supplied design and reconcile them with the data plate and test records. Confirm the applicable category before agreeing the marking; arrange the required examination scheme and examination before using qualifying equipment.
Cambridge China Bridge sources these products for UK businesses, checking the factory and the documents before shipment. See factory verification. For repeat volumes, see container programmes.
Frequently asked questions
What is the UK import duty on steel air receivers from China?
The selected heading 7311 lines carry 2% duty for goods from China in the supplied tariff snapshot. No anti-dumping or countervailing duty is recorded.
Do steel air receivers need CE or UKCA marking?
For receivers requiring conformity marking, CE or UKCA marking is accepted for the Great Britain market. Check the applicable vessel category and obtain English instructions.
What should I ask the Chinese receiver factory for?
Request an approved drawing, steel specification, pressure and capacity ratings, applicable category, design documents, test records and any applicable declaration of conformity.
Can I use an imported air receiver straight away?
Confirm applicability to your installed system before operation.