Sourcing disposable vaginal specula from China
Disposable vaginal specula from China have an indicated UK duty of 0% under 9018 90 84 00, subject to classification. Before sale in Great Britain, check medical-device conformity, MHRA registration and the Chinese manufacturer's UK Responsible Person. Cambridge China Bridge sources disposable vaginal specula.

Duty and classification for disposable vaginal specula
Read from the UK Trade Tariff on 30 September 2026, heading 9018 covers medical, surgical, dental and veterinary instruments and appliances. The candidate line for disposable vaginal specula is 9018 90 84 00, other instruments and appliances. The table shows product variants sharing that line, rather than separate tariff classifications.
This line carries 0% duty for goods from China, with no anti-dumping or countervailing measure and no suspension recorded. The tariff attaches an import prohibition concerning torture and repression goods, import controls concerning fluorinated greenhouse gases and mercury, and related export restrictions. Their application to the proposed specula was not established from the official guidance reviewed; ask your customs broker to confirm the requirements and declaration documents.
Confirm the commodity code using the intended clinical use, materials and product documentation before ordering. The medical instruments and devices guide covers the wider heading. This guide's market requirements concern Great Britain; Northern Ireland has different medical-device rules.
| Goods | Commodity code | Duty | Anti-dumping or countervailing duty on China |
|---|---|---|---|
| Disposable vaginal specula, screw-lock type | 9018 90 84 00 | 0% | None |
Specify blades, locking mechanism and sterile presentation
Specify blade length, width, opening range, material, transparency and locking mechanism against an approved drawing and sample. Agree the size mix and individual packaging. State whether the product is supplied sterile or non-sterile, its intended clinical use and the wording of the single-use claim.
Before placing the device on the Great Britain market, confirm MHRA registration and the Chinese manufacturer's UK Responsible Person. Confirm with MHRA whether the importer needs to notify the manufacturer or UK Responsible Person of its intention to import, and how any importer details should be submitted. Match the conformity documentation and accepted CE or UKCA route to the exact product. For sterile models, request sterilisation validation, sterile-barrier testing and shelf-life evidence.
Worked duty example
Illustrative example, not a quote: Illustrative small-business order of mixed-size disposable vaginal specula under 9018 90 84 00, invoiced at £10,000 free on board, with £900 of freight and insurance to the UK. The customs value is £10,900. Duty at 0% is £0. Import VAT at 20% is charged on the customs value plus duty, £10,900, so it is £2,180. With no duty, the only import tax is the VAT, which a VAT-registered importer can usually reclaim. The import duty and VAT guide explains each step.
Inspection checklist
Blades: compare dimensions with the drawing; inspect edges, moulding flash, cracks and surface defects. Check transparency and the consistency of the size markings.
Locking mechanism: open, lock and release samples against the agreed functional specification. Check for slipping, jamming, unexpected closure and fracture at hinges or screw threads.
Packaging: inspect individual seals, punctures and transit damage. Match sterile claims, batch numbers, expiry dates and English instructions to the approved artwork and supporting documents.
Arrival records: reconcile carton contents and size mix with the order, retain batch identification and isolate damaged packs. Quality inspection explains inspection stages; visual inspection alone does not establish sterility.
Working out your own order? Send us the product on WhatsApp and we reply the same working day: WhatsApp us
What goes wrong
Watch for blades that differ from the approved sample, rough moulded edges, brittle hinges and locks that slip when opened. A familiar size name can conceal different blade dimensions. Put the drawing, functional checks and acceptance criteria into the purchase specification.
A sterile claim on a pouch does not replace validation evidence. Damaged seals, mismatched batch records or documents covering another model should stop stock release pending investigation. Keep opened inspection samples separate from saleable sterile stock.
Cambridge China Bridge sources these products for UK businesses, checking the factory and the documents before shipment. See factory verification. For components and parts, see sourcing for manufacturers.
Frequently asked questions
What is the UK import duty on disposable vaginal specula from China?
The supplied tariff data shows 0% under candidate code 9018 90 84 00, with no anti-dumping or countervailing measure. Confirm classification and attached controls before shipment.
Does the Chinese manufacturer need a UK Responsible Person?
Confirm with MHRA whether the manufacturer needs a UK Responsible Person to place its devices on the Great Britain market. Confirm the appointment and MHRA device registration before sale.
What should I request for sterile vaginal specula?
Request sterilisation validation, sterile-barrier packaging tests and shelf-life evidence matching the product. Check batch and expiry markings against the shipment records.
How do I compare speculum sizes between factories?
Compare blade length, width and opening range on drawings and samples. Specify the locking mechanism and check operation; do not rely on size names alone.