Sourcing Woltmann water meters from China
Woltmann water meters and their parts from China carry 0% UK duty, with no anti-dumping or countervailing duty shown. For meters intended for regulated uses, confirm conformity assessment and marking requirements with the relevant authority before sale. Specify flange dimensions, flow range and installation position. Cambridge China Bridge sources Woltmann water meters.
Buying from China for a business? How our UK China sourcing agent service works · China sourcing agent for small orders and first imports

UK duty on Woltmann water meters
Heading 9028 covers gas, liquid and electricity supply or production meters and their parts. Complete Woltmann water meters fall within liquid meters, code 9028 20 00 00. The table repeats this code for different meter configurations; these are not separate tariff subdivisions. Water-meter parts and accessories fall within 9028 90 90 00, subject to confirming the individual item.
Read from the UK Trade Tariff on 1 October 2026, both relevant lines carry 0% duty for goods from China. The supplied tariff data shows no anti-dumping or countervailing duty, suspension or attached import control for these lines. This tariff position does not replace the product requirements for regulated water meters.
Confirm the commodity code using the product description, function and whether the shipment contains complete meters or separate parts. See the wider heading discussion in the mechanical multi-jet water meter guide.
| Goods | Commodity code | Duty | Anti-dumping or countervailing duty on China |
|---|---|---|---|
| Horizontal-axis Woltmann water meters | 9028 20 00 00 | 0% | None |
| Parts and accessories for Woltmann water meters | 9028 90 90 00 | 0% | None |
Specify the Woltmann meter and pipe connection
Specify the rotor arrangement, permitted installation position, pipe bore, flange drilling, face-to-face length and pressure rating. Give the factory the expected operating flow range and water temperature, rather than selecting a meter from pipe diameter alone. Agree the required upstream and downstream installation conditions against the supplier's instructions.
For regulated uses, confirm water-meter conformity assessment and marking requirements under the Measuring Instruments Regulations 2016 with the relevant authority. Match the assessment evidence to the exact model and configuration. Supplementary metrology marking is required alongside either UKCA or CE marking. Settle the applicable route through testing and certification before ordering.
For drinking-water service, check evidence for the wetted body, coating, seals and measuring insert under the applicable water fittings requirements. In England and Wales, water undertakers enforce the Water Supply (Water Fittings) Regulations 1999. Specify mechanical indication or pulse output, and agree pulse scaling, cable connection and replacement-insert compatibility where relevant.
Worked duty example
Illustrative example, not a quote: Illustrative order of 20 large flanged Woltmann water meters under 9028 20 00 00, invoiced at £45,000 free on board, with £2,000 of freight and insurance to the UK. The customs value is £47,000. Duty at 0% is £0. Import VAT at 20% is charged on the customs value plus duty, £47,000, so it is £9,400. With no duty, the only import tax is the VAT, which a VAT-registered importer can usually reclaim. The import duty and VAT guide explains each step.
Inspection checklist
Connection: measure flange drilling and face-to-face length against the approved drawing; check sealing faces, coating damage and flow-direction arrows.
Measurement: test samples on a calibrated bench at minimum, transitional, permanent and overload flows; compare results with the agreed accuracy specification and installation position.
Evidence: match model identification, serial numbers, conformity and metrology markings to the assessment evidence; check drinking-water material evidence against the actual wetted components.
Integrity and output: check pressure-test records, leaks, register readability and tamper seals; compare pulse counts with the indicated volume where fitted. Include these checks in the inspection brief.
Working out your own order? Send us the product on WhatsApp and we reply the same working day: WhatsApp us
What goes wrong
A meter can match the pipe bore while its flange drilling or overall length prevents installation. An unsuitable flow range can leave routine consumption near the meter's least sensitive operating region. Watch for low-flow error, sticking registers, damaged sealing faces and leaking joints.
Certificates may describe a different measuring insert or configuration from the supplied meter. Replacement inserts, coatings or seals can also differ from the approved sample. Freeze the component specification and compare the delivered batch with it; test pulse scaling before connecting the meter to a monitoring system.
Cambridge China Bridge sources these products for UK businesses, checking the factory and the documents before shipment. See factory verification. For components and parts, see sourcing for manufacturers.
Frequently asked questions
What is the UK import duty on Woltmann water meters from China?
The supplied tariff data shows 0% duty on complete liquid meters and water-meter parts, with no anti-dumping or countervailing duty, suspension or attached import control.
Do Woltmann water meters need UKCA or CE marking?
For regulated uses, confirm conformity assessment requirements with the relevant authority. Check that the assessment evidence covers the supplied model and configuration.
What should I specify for a flanged Woltmann meter?
Specify pipe bore, flange drilling, face-to-face length, pressure rating, operating flow range, water temperature and installation position. Agree pulse output and scaling where required.
How do I check a Woltmann water meter shipment?
Check flange dimensions, sealing faces, markings and model evidence. Test sampled meters for accuracy and leaks, and compare pulse counts with the register where pulse output is fitted.